» Bathrive-V6 furnace temperature tester » Bathrive-SU furnace temperature tester » Bathrive-FBT furnace temperature tester » Bathrive-GX wireless furnace temperature tester » Bathrive-TMS online furnace temperature monitoring system » Slim Series Wireless Furnace Temperature Tester » 2D solder paste thickness gauge » 3D solder paste thickness gauge » High temperature insulation box » Auxiliary temperature measurement device » Oxygen concentration analyzer
- About Us
- News
- Case Video
- Cooperative partner
- Contact us
-
English
Products
Oxygen concentration analyzer RF-400
Category: Oxygen concentration analyzer
Commodity name: Oxygen concentration analyzer RF-400 Advantages: RF-400, an oxygen analyzer specially developed for nitrogen reflow soldering equipment. Equipped with a probe protector to achieve unprecedented high durability. At the same time, it is easy to operate and small in size, making it the best choice for equipment assembly such as nitrogen reflow soldering.Model: RF-400 Small design is most suitable for carrying with nitrogen reflow oven equipmentSpecification: ●Measurement method / zirconia oxygen concentration battery type●Measurement range / 10ppm ~ 100vol%●Measuring range (display)/
- DESCRIPTION
- Commodity name: Oxygen concentration analyzer RF-400
Advantages: RF-400, an oxygen analyzer specially developed for nitrogen reflow soldering equipment. Equipped with a probe protector to achieve unprecedented high durability. At the same time, it is easy to operate and small in size, making it the best choice for equipment assembly such as nitrogen reflow soldering.
Model: RF-400 Small design is most suitable for carrying with nitrogen reflow oven equipment
Specification:
●Measurement method / zirconia oxygen concentration battery type
●Measurement range / 10ppm ~ 100vol%
●Measuring range (display)/ 0-1/10/100/1000/10000ppm1/10/100%10-20 ~ 10-9 atm
1 range can be selected from the output range/above range
●Sampling method/ continuous suction
●Supply gas flow rate/ 1000 ~ 2000ml/min
●Sampling gas conditions/pressure below 29kPa
●Error/within ±1% FS (0-10000ppm range or above); within ±2% FS (0-10000ppm range is not full); (0-10ppm or less, atm range is not guaranteed)
●Dimensions / 210W×300D×H134
●Power AC100V ~ 240V 50/60Hz
●Gas temperature / below 40℃